FAQ
Q: What information should I provide before order?
A: Please confirm the input data, output data and another function you need.
Q: How long is your warranty period?
A: Dedication to our customers and recognition of industry requirements, we announced 5 years warranty at 2 0 1 3 and continues to drive our development of new products and solutions to meet our customers’ needs.
Q: Are you trading company or manufacturer ?
A: We are manufacturer, providing own brand product and also ODM/OEM services.
Q: How long is your delivery time?
A: ≤ 20 pcs, generally it is 3 days after 100% down-pay; 20–100 pcs, it is 3-10 days according to quantity; More than 100 pcs, pls contact with our support.
Q: What is your terms of payment ?
A: 100% T/T in advance.
General
- Number of channels : 1input/2outputs
- Dielectric strength : Between non-intrinsically safe part and intrinsically safe part≥2500VAC,Between power supply part and non-intrinsically safe part≥500VAC
- Output accuracy(20°C) : 0.1%F.S. .
- Temperature drift : 0.005%F.S./℃
- Response time : Reach 90% of final value in 2ms
- Insulation resistance : Between non-intrinsically safe part and intrinsically safe part≥100MΩ,Between power supply part and non-intrinsically safe part≥100MΩ
- Electromagnetic compatibility : According to IEC 61326-1(GB/T 18268), IEC 61326-3-1
- EX marking : [Ex ia Ga]ⅡC [Ex iaD]
- Weight Approx : Approx 115g
- Field apparatus : 2-wire HART Transmitter,3-wire Transmitter,Current Source
- Suitable location : zone 0;zone 1;zone 2;IIA;IIB;IIC;T4~T6
Input data
- Input signal : 0~20mA;4~20mA;HART
- Open circuit : ≤28V
- Distribution : Voltage: ≥15.5V at 20mA
- Normal working current : ≤25mA
Output data
- Output signal : 0~20mA;4~20mA;HART;0~5V;1~5V
- Current output load resistance : RL≤300Ω,RL≥250Ω(HART)
- Voltage output load resistance : RL≥330kΩ
Power supply
- Supply voltage(Ue) : 20~35V DC
- Power protection : Reverse protection of power supply
- Current consumption : ≤75mA (at 24Vdc supply,20mA output)
- Power supply mode : Independent power supply
- Power connecting mode : DIN Rail BUS;Terminal
Dimensions
- Depth : 118.9mm
- Height : 106.0mm
- Width : 12.5mm
Housing
- Brand : Phoenix
- Material : PC
- Degree of protection : IP20
- Flammability rating : UL94/V0
- Colour : gray
Product approvals
- Approvals : IECEx;NEPSI;SIL
Standard/Specification
- NEPSI : [Ex ia Ga] IIC Comply with standard: GB 3836.1、GB 3836.4、GB 3836.20 [Ex iaD] Comply with standard: GB 12476.1、GB 12476.4
- IECEx : [Ex ia Ga] IIC Comply with standard: IEC 60079-0、IEC 60079-11、IEC 60079-26
- Functional safety : SIL2 Comply with standard: IEC 61508
Safe data(EX)
- Max. r.m.s. a.c. or d.c. voltage Um : 250V
- Max.output voltage Uo : 28V(7,8,9,10) 1.2V(9,10)
- Max.output current Io : 93mA(7,8,9,10)
- Max.output power Po : 651mW(7,8,9,10)
- IIC Max. external inductance Lo : 4.2mH(7,8,9,10)
- IIC Max. external capacitance Co : 0.083μF(7,8,9,10)
- IIB Max. external inductance Lo 1: 2.6mH(7,8,9,10)
- IIB Max. external capacitance Co : 0.65μF(7,8,9,10)
- IIA Max. external inductance Lo : 33.6mH(7,8,9,10)
- IIA Max. external capacitance Co : 2.15μF(7,8,9,10)
- Max. Input voltage Ui : 20V(9,10)
- Max. Input current Ii : 120mA(9,10)
- Max. internal inductance Li : 0.54μH(7,8,9,10端子间)
- Max. internal capacitance Ci : 0μF(7,8,9,10)
Safety-related parameters(SIL)
- Type of equipment : Type A
- Safety integrity level(SIL) : 3
- Mode of operation (Low demand) : IEC 61508-Low demand
- Safe failure fraction(Low demand) : (SFF) 0.9887
- Proof test interval(Low demand) : (PTI) 4 years
- λS(Low demand) : 139 FIT
- λSD(Low demand) : 4.36 FIT
- λDD(Low demand) : 241 FIT
- Average probability : of dangerous failure on demand(Low demand) (PFDAVG) 7.63E-05
- Diagnostic coverage(Low demand) (DC) : 0.9822
- Mode of operation (High demand) : IEC 61508-High demand
- Safe failure fraction(High demand) : (SFF) 0.9887
- Proof test interval(High demand) : (PTI) 4 years
- λS(High demand) : 139 FIT
- λDU(High demand) : 4.36 FIT
- λDD(High demand) : 241 FIT
- Average frequency of a dangerous failure per hour(High demand) (PFH) : 4.36E-09
- Diagnostic coverage(High demand) (DC) : 0.9822
EMC data
- Electrical fast transient/burst immunity : According to:IEC 61326-3-1
- Surge immunity : According to:IEC 61326-3-1
- Radiated,radio-frequency,electromagnetic field immunity : According to:IEC 61326-3-1
- Electrostatic discharge immunity : According to:IEC 61326-3-1
- Immunity to conducted disturbances, induced by radio-frequency fields : According to:IEC 61326-3-1
- Immunity to conducted, common mode disturbances in the frequency range 0 Hz : to 150 kHz According to:IEC 61326-3-1
Data communication
- HART : Yes
Operating conditions
- Ambient temperature : -20℃~+60℃
- Storage temperature : -40℃~+80℃
- Relative humidity : 10%~90%
- Environmental requirements : The air should not contain any medium corrupting the coat of chrome,nickel and silver.Moreover,violent quiver and
- impact or any cause of electromagnetic induction (such as big current or spark,etc.)must be avoided when using
Connection data
- Conductor cross section solid range : 0.5~2.5mm²
- Conductor cross section flexible range : 0.5~2.5mm²
- Conductor cross section AWG min. : 12
- Conductor cross section AWG max. : 24
- Stripping length : 8mm
- Screw thread : M3
- Connection method : Screw connection
- Tightening torque min. : 0.5 Nm
- Tightening torque max. : 0.6 Nm
Installation
- Mounting type : DIN35mm
Notes
- 1. It is not allowed to use HHC (HART hand-held communicator) in hazardous area and safe area at the same time.2. HHC (HART hand-held communicator) used in hazardous area must have an EX certification.